Your Trusted Partner in Electronics Supply Chain. Inquire Now!

Explore Our Latest Smart Electronics Collection.

high-voltage-dc-contactor, , /high-voltage-dc-contactor
Inquiry
Inquiry

PNC113CDA NC Contactor 30A

Sensata Gigavac PNC113CDA PNC113 normally closed MiniTACTOR, 30A, 1500VDC switching, 24VDC coil, M3 coil studs, M4 power studs

Request a Quote
  • Overview

Overview

Sensata Gigavac PNC113CDA

The Sensata Gigavac PNC113CDA is a PNC113 Series normally closed MiniTACTOR designed for high-voltage DC discharge and dump switch applications. This model is configured with a 30 A current rating, 1500VDC maximum operating voltage, a 24VDC coil, M3 coil studs, M4 power studs, and an SPST-NC main contact. The 1500VDC value refers to the main power/load circuit, while the 24VDC value refers to the coil/control circuit used to change the contact state.

Category Relays - Contactors, Electromechanical
Manufacturer Sensata-Gigavac Clean Energy
Manufacturer Product Number PNC113CDA
Series PNC113 MiniTACTOR
Product Type Normally Closed High Voltage DC Contactor
Mounting Type Chassis Mount / Panel Mount
Coil Voltage 24VDC
Contact Form SPST-NC, 1 Form Y Main Contact
Contact Rating Current 30 A at 25°C with 8 AWG conductor
Current Rating at 65°C 15 A with 8 AWG conductor
Switching Voltage 1500VDC Max
Termination Style Stud Terminals
Coil Terminals M3 Studs
Power Terminals M4 Studs
Auxiliary Contact None
Operating Temperature -40°C to +65°C
Must Operate Voltage 15 VDC
Must Release Voltage 0.4 VDC Min
Operate Time 25 ms Max
Release Time 8 ms Max
Coil Current 85 mA at nominal voltage
Coil Resistance 280 Ohms +/-10%
Dielectric Withstanding Voltage 4300 VRMS at sea level
Mechanical Life 100,000 Cycles
Typical Weight Approx. 135 g

Product Description

The Sensata Gigavac PNC113CDA is not a standard normally open contactor. It is a normally closed MiniTACTOR for circuits that need the main contact closed when the coil is not energized. In the resting state, the main contact is closed. When the 24VDC coil is energized, the contactor opens the main contact. When coil power is removed, the contact returns to the closed state.

This operating behavior makes PNC113CDA especially useful for capacitor discharge, dump switch, fail-closed discharge, and stored-energy removal applications. In an inverter, energy storage system, test cabinet, or battery-connected HVDC circuit, a normally closed discharge contactor can provide a default current path when control power is removed. The contactor is the switching element; the final discharge current and time depend on the complete circuit, including resistors, fuses, wiring, and thermal design.

The full model number should be used in backend records and product listings. “PNC113” identifies the 30 A normally closed MiniTACTOR family. The “C” indicates the 24VDC coil version. The “D” indicates M3 stud coil terminals. The “A” indicates M4 stud power terminals. This model does not include an auxiliary contact, so system feedback must be handled separately if position monitoring is required.

Key Features

  • Normally closed SPST-NC main contact for discharge and dump switch circuits.
  • 30 A current rating at 25°C with suitable 8 AWG conductor.
  • 1500VDC maximum operating voltage for high-voltage DC applications.
  • 24VDC coil for common industrial, battery, and control systems.
  • M3 coil studs and M4 power studs for compact screw-terminal installation.
  • Small MiniTACTOR package with typical weight around 135 g.
  • Bidirectional current carrying, make, and break capability.
  • Can be mounted in any position or axis.
  • Designed for capacitor discharge and HVDC dump applications.
  • CE conforming design for compact high-voltage DC systems.

Applications

The Sensata Gigavac PNC113CDA is commonly used in high-voltage DC circuits where the default state must be closed rather than open. Typical applications include capacitor discharge circuits, inverter DC link discharge, battery energy storage safety circuits, photovoltaic power equipment, HVDC test systems, power conversion cabinets, charger discharge circuits, and industrial dump switch systems.

Because the main contact is normally closed, PNC113CDA should be selected only when the electrical design specifically requires this behavior. For example, a system may energize the coil during normal operation to hold the discharge path open. When the system shuts down or loses control power, the contactor releases and closes the discharge path through a designed resistor network.

Design Notes

The 1500VDC and 24VDC ratings describe separate circuits. The 1500VDC rating applies to the main contact/load circuit. The 24VDC rating applies to the coil circuit that changes the contact state. A 24V control output may open the normally closed contactor while the main terminals are connected to a much higher DC voltage, provided the full circuit stays within the contactor ratings.

PNC113CDA does not include built-in auxiliary feedback. If the control system needs confirmation of contactor state, use external sensing or a system-level monitoring method. The coil suppression device is not built into the contactor, so the recommended external suppression for the 24V coil should be considered during control circuit design.

For discharge applications, verify discharge resistor value, peak current, energy rating, time constant, cable size, insulation spacing, temperature rise, and fault behavior. The contactor is rated for 30 A continuous carry at 25°C, but current capability changes with conductor size, ambient temperature, and duty cycle.

Why Choose Sensata Gigavac PNC113CDA

PNC113CDA is a strong choice when a compact normally closed contactor is needed for HVDC discharge functions. Compared with larger high-current contactors, it provides a smaller and lighter solution for 30 A circuits. Compared with normally open P Series MiniTACTOR models, PNC113CDA provides the opposite default state, which is essential for fail-closed discharge and dump switch designs.

For backend product listings, write the full name as Sensata Gigavac PNC113CDA. Avoid shortening it to PNC113 only, because related models can use 12VDC, 24VDC, or 48VDC coils. PNC113CDA specifically identifies the 24VDC coil, M3 coil stud, M4 power stud version.

FAQ

Is PNC113CDA normally open or normally closed?
PNC113CDA is normally closed. The main contact is SPST-NC, also described as 1 Form Y.

Is PNC113CDA a 1500V or 24V contactor?
It uses both values for different circuits. The main contact is rated up to 1500VDC, while the coil/control circuit is 24VDC.

Does PNC113CDA have an auxiliary contact?
No. This model does not include an auxiliary contact.

What is PNC113CDA used for?
It is mainly used for capacitor discharge, dump switch, and fail-closed high-voltage DC circuits.

PNC113CDA NC Contactor 30A

Sensata Gigavac PNC113CDA PNC113 normally closed MiniTACTOR, 30A, 1500VDC switching, 24VDC coil, M3 coil studs, M4 power studs

Request a Quote
{"cf_related_products":{"field_type":"product","type":"array","value":[{"id":400,"title":"GTM401BAB DC Contactor 400A","pic":"https://sc04.alicdn.com/kf/H9072ce162b954690a5b723adc79a533fC.png","pics":"https://sc04.alicdn.com/kf/H9072ce162b954690a5b723adc79a533fC.png,https://sc04.alicdn.com/kf/H7abdf66d6af74031b62267056139e63cs.png,https://sc04.alicdn.com/kf/H51764353bdf3459188926df36a79bdf1h.png,https://sc04.alicdn.com/kf/H36df9ddfe7774a3990d9144b54fcc7f7v.png,https://sc04.alicdn.com/kf/Hc078042d060a48299f9164aaf893fa0fW.png,https://sc04.alicdn.com/kf/H8e42d0f76a3e4ea589542aaaac40096cZ.png","link":"/gtm401bab-dc-contactor-400a","desc":"Sensata Gigavac GTM401BAB DC Contactor The Sensata Gigavac GTM401BAB is a sealed hermetic DC contactor from the GTM400 Series, designed for high-voltage switching applications up to 1500VDC and 4...","product_price_min":"","product_price_max":"","need_show_price":0},{"id":402,"title":"PNC113BDA NC Contactor 30A","pic":"https://sc04.alicdn.com/kf/Haa2f7f3e24ed440cbb2fece4c4302a86U.png","pics":"https://sc04.alicdn.com/kf/Haa2f7f3e24ed440cbb2fece4c4302a86U.png,https://sc04.alicdn.com/kf/H9c4be320bdab4285b793b5ae28aade61c.png,https://sc04.alicdn.com/kf/H51764353bdf3459188926df36a79bdf1h.png,https://sc04.alicdn.com/kf/H36df9ddfe7774a3990d9144b54fcc7f7v.png,https://sc04.alicdn.com/kf/Hc078042d060a48299f9164aaf893fa0fW.png,https://sc04.alicdn.com/kf/H8e42d0f76a3e4ea589542aaaac40096cZ.png","link":"/pnc113bda-nc-contactor-30a","desc":"Sensata Gigavac PNC113BDA Normally Closed DC ContactorThe Sensata Gigavac PNC113BDA is a sealed normally closed DC contactor from the PNC113 MiniTACTOR Series, designed for compact HVDC discharge and ...","product_price_min":"","product_price_max":"","need_show_price":0},{"id":403,"title":"P105BDA DC Contactor 50A","pic":"https://sc04.alicdn.com/kf/Hd4e7487868af4838b9896aef0870db2dR.png","pics":"https://sc04.alicdn.com/kf/Hd4e7487868af4838b9896aef0870db2dR.png,https://sc04.alicdn.com/kf/Hb067307c530946baa5fbe3e567e89beeD.png,https://sc04.alicdn.com/kf/H51764353bdf3459188926df36a79bdf1h.png,https://sc04.alicdn.com/kf/H36df9ddfe7774a3990d9144b54fcc7f7v.png,https://sc04.alicdn.com/kf/Hc078042d060a48299f9164aaf893fa0fW.png,https://sc04.alicdn.com/kf/H8e42d0f76a3e4ea589542aaaac40096cZ.png","link":"/p105bda-dc-contactor-50a","desc":"Sensata Gigavac P105BDA DC ContactorThe Sensata Gigavac P105BDA is a sealed hermetic DC contactor from the P105 MiniTACTOR Series, designed for compact high-voltage DC switching applications that requ...","product_price_min":"","product_price_max":"","need_show_price":0},{"id":409,"title":"GXNC14CB NC Contactor 350A","pic":"https://sc04.alicdn.com/kf/H9bcb9225bcd344c5bf22f68f03659616A.png","pics":"https://sc04.alicdn.com/kf/H9bcb9225bcd344c5bf22f68f03659616A.png,https://sc04.alicdn.com/kf/Hf4eb2ac4eb5b41b78969cfc8fe5f202eu.png,https://sc04.alicdn.com/kf/H51764353bdf3459188926df36a79bdf1h.png,https://sc04.alicdn.com/kf/H36df9ddfe7774a3990d9144b54fcc7f7v.png,https://sc04.alicdn.com/kf/Hc078042d060a48299f9164aaf893fa0fW.png,https://sc04.alicdn.com/kf/H8e42d0f76a3e4ea589542aaaac40096cZ.png","link":"/gxnc14cb-nc-contactor-350a","desc":"Sensata Gigavac GXNC14CB Normally Closed DC ContactorThe Sensata Gigavac GXNC14CB is a sealed normally closed DC contactor from the GXNC14 Series, designed for 350A current switching in power systems ...","product_price_min":"","product_price_max":"","need_show_price":0},{"id":464,"title":"P125FDA DC Contactor 30A","pic":"https://sc04.alicdn.com/kf/H8c3491f8b7d24e0e8d692d774ea0efef5.png","pics":"https://sc04.alicdn.com/kf/H8c3491f8b7d24e0e8d692d774ea0efef5.png,https://sc04.alicdn.com/kf/Hec3d3d60a3fb4dc7af2ea74725cc70eaZ.png,https://sc04.alicdn.com/kf/H51764353bdf3459188926df36a79bdf1h.png,https://sc04.alicdn.com/kf/H36df9ddfe7774a3990d9144b54fcc7f7v.png,https://sc04.alicdn.com/kf/Hc078042d060a48299f9164aaf893fa0fW.png,https://sc04.alicdn.com/kf/H8e42d0f76a3e4ea589542aaaac40096cZ.png","link":"/p125fda-dc-contactor-30a","desc":"Sensata Gigavac P125FDA DC Contactor OverviewThe Sensata Gigavac P125FDA is a sealed hermetic DC contactor from the P125 MiniTACTOR Series, designed for compact high-voltage DC switching applications ...","product_price_min":"","product_price_max":"","need_show_price":0},{"id":465,"title":"PNC113FDA NC Contactor 30A","pic":"https://sc04.alicdn.com/kf/H4676023ca75745d49f9ee555d061705fl.png","pics":"https://sc04.alicdn.com/kf/H4676023ca75745d49f9ee555d061705fl.png,https://sc04.alicdn.com/kf/Hec3d3d60a3fb4dc7af2ea74725cc70eaZ.png,https://sc04.alicdn.com/kf/H51764353bdf3459188926df36a79bdf1h.png,https://sc04.alicdn.com/kf/H36df9ddfe7774a3990d9144b54fcc7f7v.png,https://sc04.alicdn.com/kf/Hc078042d060a48299f9164aaf893fa0fW.png,https://sc04.alicdn.com/kf/H8e42d0f76a3e4ea589542aaaac40096cZ.png","link":"/pnc113fda-nc-contactor-30a","desc":"Sensata Gigavac PNC113FDA DC Contactor The Sensata Gigavac PNC113FDA is a sealed normally closed DC contactor from the PNC113 MiniTACTOR Series, designed for HVDC discharge and dump switch applic...","product_price_min":"","product_price_max":"","need_show_price":0}],"config":""}}

Related Products

Explore premium ICs, sensors, and power controls to support your advanced technical requirements.

pnc113cda nc contactor 30a-2

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp / Mobile Phone
Company Name
Part Number
Message
0/1000
Attachment
Please upload at least an attachment (Optional)
Up to 5 files, each no larger than 30MB. Supported formats: jpg, jpeg, png, pdf, doc, docx, xls, xlsx, csv, txt, stp, step, igs, x_t, dxf, prt, sldprt, sat, rar, zip.