Airpax JAE 100 A DC circuit breaker with a vertical surface restriction and separate auxiliary switch markings.
The Airpax JAE-1-1REC4-41066-100 is the 100 A variant of a JAE hydraulic magnetic circuit breaker for a specified DC equipment assembly. The photos show the full housing, the device label and the front marking of 100. This listing is intended for buyers matching an existing part number or a controlled bill of materials. Do not select a nearby JAE variant by appearance. Start with the complete ordering reference and the equipment maker's approved replacement record.
The photographed label restricts use to a vertical surface and says the device is not for general use. For a panel replacement, make that restriction the first decision in the review. If your drawing calls for a different orientation or the device would be used in another assembly, stop the substitution review until the responsible engineer confirms an approved part. A mechanically similar Airpax JAE circuit breaker is not automatically suitable for a different application.
The housing photos are useful for comparing the silhouette, handle location and visible openings. They do not give you a complete dimensional drawing, fastener information or an approved clearance. Mark the orientation of the existing unit in the panel drawing and show the handle relative to the cabinet opening. If the photograph appears rotated, use the equipment documentation to resolve the physical orientation. Do not rely on how a product photo is displayed to decide the required mounting position.
The main label of this 100 A DC circuit breaker shows a maximum voltage marking of 160 with a DC symbol, AIC 10,000, delay code 53 and a separate trip amps entry of 125. Read those entries separately. The trip entry is not the nominal current and the delay code is not a duration in seconds. The published JAE series data describes several options; confirm the applicable curve and interruption conditions for the exact model before qualifying a replacement. Do not use a series maximum as the rating for every configuration.
The same label marks the auxiliary switch separately, at 1 A 80 V DC and 10 A 250 V AC. These markings apply to the auxiliary switch, not to the main power path. When the Airpax JAE circuit breaker is used in equipment that monitors switch position, include the required auxiliary contact arrangement and control circuit conditions in the review. The label and product photos do not establish which control wires belong to a terminal or how a specific panel should be wired. Use the approved device drawing and equipment wiring documentation for that work.
JAE-1-1REC4-41066-100 and a reference ending in 250 must remain separate purchase lines, even when the family and the middle portion of the identifier match. Do not shorten the purchase order entry to the shared stem. Carry the final number through the quote, order and receiving record. If your purchasing system has a short description field, keep the full identifier in its manufacturer part number field and put the abbreviated description in a separate field. The front marking gives an additional visual check for the 100 A DC circuit breaker but does not replace the complete label.
For a planned maintenance outage, ask the purchaser to place the equipment asset number and approved part reference on the same request. This avoids an apparent match being assigned to the wrong panel when several service jobs share a common order. If the old breaker label is unreadable, ask the equipment owner to retrieve the approved parts record. A clear picture of a similar housing is useful background but cannot fill in a missing ordering suffix.
At receipt, compare the quoted identifier against the device label, the front marking and the approved purchase order. Check the visible enclosure and handle against the agreed reference. Set aside any item whose final suffix or label differs rather than accepting it as another Airpax JAE circuit breaker. If a functional inspection is required, use the approved acceptance procedure; matching the markings is an identity check, not a performance test.
For a controlled service spare, add a note to the maintenance record explaining why the Airpax JAE circuit breaker was accepted for that equipment revision. Include the drawing reference, the person responsible for approval and any installation restriction that must follow the spare. If the 100 A DC circuit breaker is held for several sites, identify which panel records authorize it. This gives the next buyer an approved reference rather than a part that only looks familiar in a storeroom.
No. Fit alone is not approval, and the final number is part of the ordered configuration. Keep the variants separate and obtain a documented disposition for any proposed change.
No. The photographed unit distinguishes the auxiliary switch from the main circuit markings. Ask for the exact configuration documentation if the panel uses both paths.
The label shows a vertical surface restriction. Do not assume another orientation is allowed. Ask the equipment maker or responsible engineer to confirm the correct configuration for your assembly.
Use Request a Quote for JAE-1-1REC4-41066-100. Include the quantity, destination and any exact match or inspection requirements so the quotation can address the part you actually need.
Airpax JAE 100 A DC circuit breaker with a vertical surface restriction and separate auxiliary switch markings.