GX12FCB DC Contactor 225A

Sensata Gigavac GX12FCB is a sealed GX12 DC contactor, 225A, 800VDC max switching, 48VDC coil, wire leads, NO auxiliary contact

Request a Quote
  • Overview

Overview

Sensata Gigavac GX12FCB DC Contactor Overview

The Sensata Gigavac GX12FCB is a sealed hermetic DC contactor from the GX12 Series, designed for 225A current switching in power systems up to 800VDC. It uses a 48VDC control coil, chassis mounting, stud and wire lead termination, and a normally open auxiliary contact. This model is suitable for electric vehicles, battery energy storage systems, industrial DC power distribution, marine power control, solar equipment, power management systems, and OEM battery disconnect modules. In this model, 800VDC refers to the main contact switching voltage, while 48VDC refers to the coil voltage used to operate the contactor.

Category Relays - Contactors (Electromechanical)
Manufacturer Sensata-Gigavac Clean Energy
Series GX12
Packaging Bulk
Part Status Active
Mounting Type Chassis Mount
Coil Voltage 48VDC
Contact Form SPST-NO (DM) (1 Form X)
Auxiliary Contact SPST Normally Open
Contact Rating Current 225 A
Switching Voltage 800VDC - Max
Features Auxiliary Contacts, Sealed - Hermetically
Termination Style Stud, Wire Leads
Operating Temperature -55°C ~ 85°C
Must Operate Voltage 28 VDC
Must Release Voltage 1.8 VDC
Operate Time 30 ms
Release Time 12 ms
Coil Current 160 mA
Coil Power 7.6 W
Coil Resistance 300 Ohms

Product Description

The Sensata Gigavac GX12FCB DC contactor is designed for reliable high-voltage DC switching in compact battery and power control systems. As part of the GX12 Series, this model provides a 225A contact current rating and up to 800VDC maximum switching voltage. It is commonly selected for electric vehicles, battery energy storage systems, solar power equipment, marine power systems, industrial DC cabinets, and OEM battery disconnect assemblies.

The GX12FCB uses an SPST-NO main contact arrangement, also described as 1 Form X. The main power contact remains open when the coil is not energized and closes when the 48VDC coil receives the correct control signal. This allows a low-voltage control circuit to manage a higher-voltage DC load path. The 800VDC value belongs to the main switching circuit, while the 48VDC value belongs only to the coil control circuit.

A key advantage of the Sensata Gigavac GX12FCB is its sealed hermetic construction. The sealed body helps protect the internal contact system from dust, humidity, oxidation, and contamination. This makes the GX12FCB suitable for mobile equipment, outdoor battery systems, industrial power modules, and vehicle platforms where vibration, moisture, and harsh operating conditions can reduce the service life of ordinary open-frame contactors.

The GX12FCB also includes a normally open auxiliary contact. This auxiliary contact can provide feedback to a controller, battery management system, or safety circuit. It is useful for confirming contactor state, supporting interlock logic, or adding diagnostic feedback in battery disconnect and power distribution systems.

This model uses stud and wire lead termination for harness-based installation. The configuration is practical for power distribution boxes, battery disconnect modules, EV control cabinets, and industrial assemblies where the main power terminals require secure stud connections and the coil or auxiliary circuits are routed through wire leads.

Key Features

  • Genuine Sensata Gigavac GX12 Series DC contactor
  • 225A contact rating for DC power control
  • 800VDC maximum switching voltage for high-voltage systems
  • 48VDC coil for control circuit operation
  • SPST-NO main contact form for normally open switching
  • SPST normally open auxiliary contact for feedback or interlock use
  • Hermetically sealed construction for harsh environments
  • Stud and wire lead termination for harness-based installation
  • 30 ms operate time and 12 ms release time
  • Suitable for EV, ESS, solar, marine, and industrial DC systems

Applications

The GX12FCB DC contactor is suitable for systems that need reliable connection and disconnection of DC battery, load, or charging circuits. Typical applications include electric vehicles, battery energy storage systems, solar power equipment, DC power cabinets, marine battery systems, UPS battery modules, material handling equipment, and industrial automation systems.

In a battery system, the Sensata Gigavac GX12FCB can be used as a main contactor, charge contactor, load disconnect contactor, or safety isolation device depending on the electrical design. Its 225A current rating makes it a good fit for medium-current DC platforms where sealed construction, auxiliary feedback, and stable switching performance are required.

Why Choose Sensata Gigavac GX12FCB

The Sensata Gigavac GX12FCB is a strong option when the system requires 225A current capacity, up to 800VDC switching voltage, 48VDC coil operation, sealed construction, wire lead termination, and a normally open auxiliary contact. Compared with versions without auxiliary feedback, this model gives the control system an additional status signal for diagnostics or interlock logic.

For replacement and maintenance projects, GX12FCB should be selected when the original system requires GX12 Series performance with 225A contact rating, 800VDC maximum switching voltage, 48VDC coil voltage, chassis mounting, stud and wire lead termination, and normally open auxiliary contact. Before ordering, confirm coil voltage, auxiliary contact logic, load current, switching voltage, mounting space, and terminal requirements.

FAQ

Q1: What is the full product name of GX12FCB?
A1: The full product name is Sensata Gigavac GX12FCB DC Contactor.

Q2: What is the main switching voltage?
A2: The main switching voltage is up to 800VDC maximum.

Q3: What does 48VDC mean?
A3: 48VDC is the coil voltage used to operate the contactor, not the main load voltage.

Q4: What is the current rating?
A4: The contact rating current is 225A.

Q5: Does GX12FCB include an auxiliary contact?
A5: Yes. GX12FCB includes a normally open auxiliary contact.

Q6: Where is GX12FCB commonly used?
A6: It is commonly used in EV systems, battery energy storage, DC power distribution, solar equipment, marine systems, and industrial DC control modules.

GX12FCB DC Contactor 225A

Sensata Gigavac GX12FCB is a sealed GX12 DC contactor, 225A, 800VDC max switching, 48VDC coil, wire leads, NO auxiliary contact

Request a Quote
{"cf_related_products":{"field_type":"product","type":"array","value":[],"config":""}}

Related Products

Explore premium ICs, sensors, and power controls to support your advanced technical requirements.

gx12fcb dc contactor 225a-2

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp / Mobile Phone
Company Name
Part Number
Message
0/1000
Attachment
Please upload at least an attachment (Optional)
Up to 5 files, each no larger than 30MB. Supported formats: jpg, jpeg, png, pdf, doc, docx, xls, xlsx, csv, txt, stp, step, igs, x_t, dxf, prt, sldprt, sat, rar, zip.